What is the primary function of this ultrasonic sensor?
The primary function of the Pepperl + Fuchs UC2500-F65-IE2R2-V15 ultrasonic sensor is to measure filling levels in small containers. It provides both a switch output and an analogue output for level indication.
What is the sensing range of this sensor?
The sensing range of this ultrasonic sensor is from 250 mm to 2500 mm.
Can the sensor be programmed for specific applications?
Yes, the sensor can be programmed using the SONPROG interface to adjust parameters such as measuring range limits, switch-on and switch-off points, and averaging.
What type of output does the sensor provide?
The sensor provides a switch output and an analogue output. The analogue output is a 4-20 mA current source, representing the current level as an analogue variable.
What are the environmental conditions suitable for this sensor?
The sensor operates effectively in ambient temperatures ranging from -25°C to 70°C and can be stored in temperatures from -40°C to 85°C.
What is the degree of protection offered by this sensor?
The Pepperl + Fuchs UC2500-F65-IE2R2-V15 ultrasonic sensor has an IP65 degree of protection, making it suitable for various industrial environments.
How is the sensor mounted?
The sensor can be mounted on a tank using two M5 screws. It is designed to fit tank openings with a diameter of 26 mm.
What materials are used in the construction of this sensor?
The housing of the sensor is made from PBT, while the transducer is constructed from a mixture of epoxy resin and hollow glass spheres, with polyurethane foam.
Does the sensor have any synchronisation capabilities?
Yes, the sensor can be synchronised with other sensors using the function input XI, allowing for both internal and external synchronisation.
What is the default setting for the measuring range?
The default setting for the measuring range of the UC2500-F65-IE2R2-V15 is 250 mm to 2500 mm.